| Cellar Fire |
First Hand Line
-Through front door to cellar |
| -Initially stretching through side only |
| permitted when: |
| >intergrity of 1st floor not endangered |
| >side door leads directly into cellar and |
| 1st floor |
| >room on side of house to position line |
| >time required to position line weighed |
| against potential for fire growth |
Second Hand Line
-Standby outside fire building |
| -Backup line or |
| -Enter cellar from exterior if 1st line is |
| unable or |
| -Operate on upper floors |
|
|
| 1st Floor Fire |
| First Hand Line
-Through front door to fire |
|
|
|
|
|
|
|
|
| Second Hand Line
-Standby outside fire building |
| -Backup line or |
| -Operate on upper floors or |
| -Extinguish fire in exposure |
|
|
|
| Upper Floor Fire |
| First Hand Line
-Through front door to fire |
|
|
|
|
|
|
|
|
| Second Hand Line
-Standby outside fire building |
| -Backup line or |
| -Operate on upper floors or |
| -Extinguish fire in exposure or cellar |
|
|
|
| **Do Not crowd interior stairs or landings - if you are not actively working - stand outside |
Submitted by PHOEKZEMA on Sun, 12/02/2007 - 02:50.